Durán-Aguilar, Gabriela
Main Affiliation
Preferred name
Durán-Aguilar, Gabriela
Official Name
Durán Aguilar, Gabriela
ORCID
0000-0001-9009-6664
Researcher ID
FZB-7572-2022
Scopus Author ID
57202755902
14 results
Now showing 1 - 10 of 14
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Design of a graphical user interface centered on the emotional and physiological experience of the nursing mother: NURA, a smart breast pump(Frontiers Media SA, 2026-07-15); ; ;Rossa-Sierra, Alberto ;Arrieta-Gallardo, Diana LauraGómez-Delgado, Alondra VanessaIntroduction Breastfeeding provides nutritional, immunological, and psychophysiological benefits for both the newborn and the mother. However, occupational, social, and clinical factors compel a growing number of women to resort to mechanical milk expression. Although electric breast pumps have improved the efficiency of the process, their design typically prioritizes technical variables, relegating the emotional and cognitive experience of the user to the background. This paper presents the design of a smart breast pump, named NURA, and the development of its graphical user interface (GUI), conceived from a perspective centered on the psychophysiological experience of the nursing mother. Methods The device integrates controlled suction, vibration, and breast heating, based on physiological principles of lactation, alongside a mobile application that allows for the personalized regulation of expression parameters and the recording of usage and user-reported information. The design process was structured using the Double Diamond methodology, incorporating an analysis of benchmarks, ergonomic criteria, fundamentals of lactation physiology, and user experience design principles. Functional prototypes of the hardware and the digital interface were developed, which were evaluated in pilot tests with users to analyze anatomical fit, usability, and the general perception of the system. Results Preliminary usability testing provided insights into user interactions with the proposed system. Participants were generally able to operate the prototype and its graphical interface without extensive guidance, and the evaluation helped identify opportunities for refinement in both the physical and digital components. Discussion These exploratory findings suggest the feasibility of integrating physiological and experiential considerations into the design of lactation technologies and support future studies with larger sample sizes and formal validation methods. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, 1 10Scopus© Citations 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, 1 18 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Redesigning the Common NICU Incubator: An Approach Through the Emulation of Factors Resembling the Mother’s Womb(2019) ;Arthur Jiménez, Alan Taylor ;Olivares, Sofia; 1 18 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Medical Device Design Challenges Based on Users Hierarchy and Their Correlation with Illness(2018); ;Manzano-Hernandez, Paulina; 2 10Scopus© Citations 1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experience Design: A Tool to Improve a Child’s Experience in the Use of Vesical Catheters(2019) ;Mariana Uribe-Fernández1 17 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Design of a Mobile Support Application for Teenagers Suffering from Depression in Zapopan, México(2020) ;González Cabrera, Nora Paulina ;Aragón, Victoria; 2 13 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Improving the Experience of Hemotherapy Treatment for Kids with Leukemia(2021) ;Rentería González, Magaly; ; 2 25 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Improvement in the Quality of Life of Patients with End-Stage Renal Failure Who Live Without Replacement Therapy in Mexico(2019) ;Ana Paula Pelayo ;Montserrat Pelayo1 18 - Some of the metrics are blocked by yourconsent settings
Item type:Patent, Vaso linfático artificial para linfedema secundario(PUES); ; Fuentes Aguilar, Rita QuetziquelLa presente invención se refiere a un vaso linfático “artificial” que permite la restauración de la linfa para llegar a los ganglios linfáticos, esto en los casos sin posible reconstrucción, cuyas medidas previstas para este modelo son de: válvula entrante >50-75 micras, válvula saliente <100 micras, con una presión 25 y 32 mm de Hg, con una circulación unidireccional vaso linfático 2000 micras de longitud con un diámetro de 20 micras, además de ser modular, con producción lineal, con una media máxima que podrá alcanzar hasta los 15 cms, en combinación con tramos de vaso linfático real.1 45
