Repository logo
Communities
Research Outputs
Projects
Researchers
Statistics
Feedback
  1. Home
  2. CRIS
  3. Publications
  4. A Contactless Respiratory Rate Estimation Method Using a Hermite Magnification Technique and Convolutional Neural Networks
Details

A Contactless Respiratory Rate Estimation Method Using a Hermite Magnification Technique and Convolutional Neural Networks

Journal
Applied Sciences
ISSN
2076-3417
Publisher
MDPI
Date Issued
2020
Author(s)
Brieva, Jorge  
Facultad de Ingeniería - CampCM  
Ponce, Hiram  
Facultad de Ingeniería - CampCM  
Moya-Albor, Ernesto  
Facultad de Ingeniería - CampCM  
Type
text::journal::journal article
DOI
10.3390/app10020607
URL
https://scripta.up.edu.mx/handle/20.500.12552/4118
Abstract
The monitoring of respiratory rate is a relevant factor in medical applications and day-to-day activities. Contact sensors have been used mostly as a direct solution and they have shown their effectiveness, but with some disadvantages for example in vulnerable skins such as burns patients. For this reason, contactless monitoring systems are gaining increasing attention for respiratory detection. In this paper, we present a new non-contact strategy to estimate respiratory rate based on Eulerian motion video magnification technique using Hermite transform and a system based on a Convolutional Neural Network (CNN). The system tracks chest movements of the subject using two strategies: using a manually selected ROI and without the selection of a ROI in the image frame. The system is based on the classifications of the frames as an inhalation or exhalation using CNN. Our proposal has been tested on 10 healthy subjects in different positions. To compare performance of methods to detect respiratory rate the mean average error and a Bland and Altman analysis is used to investigate the agreement of the methods. The mean average error for the automatic strategy is 3.28± 3.33% with and agreement with respect of the reference of 98%. © 2020 by the authors.
Subjects

Hermite transform

Motion video magnific...

Non-contact monitorin...

Respiratory rate

Estimation

How to cite
Brieva, J., Ponce, H., & Moya-Albor, E. (2020). A Contactless Respiratory Rate Estimation Method Using a Hermite Magnification Technique and Convolutional Neural Networks. Applied Sciences, 10(2), 607. https://doi.org/10.3390/app10020607

Creación y actualización de perfiles en Scripta+

Hosting & Support by

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify