Repository logo
  • English
  • Deutsch
  • Español
  • Français
  • Log In
    New user? Click here to register.Have you forgotten your password?
Universidad Panamericana
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • Researchers
  • Statistics
  • Feedback
  • English
  • Deutsch
  • Español
  • Français
  1. Home
  2. CRIS
  3. Publications
  4. Segmentation and motion estimation applied to fetal heart analysis using a multi-texture active appearance model and an optical flow approach
 
  • Details
Options

Segmentation and motion estimation applied to fetal heart analysis using a multi-texture active appearance model and an optical flow approach

Journal
14th International Symposium on Medical Information Processing and Analysis
Date Issued
2018
Author(s)
Escalante Ramírez, Boris
Moya-Albor, Ernesto  
Facultad de Ingeniería - CampCM  
Brieva, Jorge  
Facultad de Ingeniería - CampCM  
Guzmán Huerta, Mario
Camargo Marín, Lisbeth
Vargas Quintero, Lorena Paola P.
Type
Resource Types::text::conference output::conference proceedings::conference paper
DOI
10.1117/12.2512142
URL
https://scripta.up.edu.mx/handle/123456789/4290
Abstract
In this work we present a combination of segmentation and motion estimation methods applied to left ventricle evaluation in fetal echocardiographic images which are used for prenatal diagnosis. In our proposed scheme, several features of the ultrasound images are computed and used for both algorithms. A multiresolution framework is employed for the segmentation and motion estimation tasks. The segmentation is achieved using a multi-texture active appearance model based on the Hermite transform. The analysis is performed using the appearance models provided by Hermite coefficients up to third order. The multiresolution approach allows to obtain a robust segmentation to extract the shape of the left ventricle. The obtained results in the segmentation step are used for the motion estimation algorithm. The left ventricle is the structure used for evaluation. The main goal is to determinate the heart movement of fetal heart which can be used for disease detection, characterization and further analysis. Results of the motion estimation process are analyzed and compared with other techniques applied to heart ultrasound data. © SPIE. Downloading of the abstract is permitted for personal use only.

Copyright 2024 Universidad Panamericana
Términos y condiciones | Política de privacidad | Reglamento General

Built with DSpace-CRIS software - Extension maintained and optimized by - Hosting & support SCImago Lab

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback